Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

HILLMANENGINEERINGCOMPANYAB0E 6710d0d80751d04e2494e523 Products https://www.hillmanengineering.in/anantapur

ELGi CONSERVE aligns output with demand by adju...

  • 2024-12-10T11:26:01

ELGi CONSERVE aligns output with demand by adjusting motor speed, resulting in a decrease in power consumption corresponding to the lower demand. This assists in removing the constant load-unload cycle and the unnecessary power usage from the energy expenses. A fixed speed compressor functions within a load-unload range of at least 10 PSI around the operating pressure, whereas the ELGi VFD compressor can operate within a 2 PSI band. As compressors do not function above their required working pressure, a significant energy saving of 1% occurs for every 2 PSI decrease in operating pressure. In a constant speed compressor utilizing a star-delta starter, the starting current can be up to three times the full load current (FLC). With ELGi VFD starting, the starting current matches the full load current (FLC). This assists in preventing the use of heavily rated parts such as fuses, MCCB, cable dimensions, generator capacity, isolators, etc. In compressed air systems with varying demand patterns, the return on investment from power savings will be under 12 months.

ELGi CONSERVE aligns output with demand by adjusting motor speed, resulting in a decrease in power consumption corresponding to the lower demand. This assists in removing the constant load-unload cycle and the unnecessary power usage from the energy expenses. A fixed speed compressor functions within a load-unload range of at least 10 PSI around the operating pressure, whereas the ELGi VFD compressor can operate within a 2 PSI band. As compressors do not function above their required working pressure, a significant energy saving of 1% occurs for every 2 PSI decrease in operating pressure. In a constant speed compressor utilizing a star-delta starter, the starting current can be up to three times the full load current (FLC). With ELGi VFD starting, the starting current matches the full load current (FLC). This assists in preventing the use of heavily rated parts such as fuses, MCCB, cable dimensions, generator capacity, isolators, etc. In compressed air systems with varying demand patterns, the return on investment from power savings will be under 12 months.

  • 2024-12-10T11:26:01

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us